Skip to main content
Report File
Date Issued
Submitting OIG
Department of the Interior OIG
Other Participating OIGs
Department of the Interior OIG
Agencies Reviewed/Investigated
Department of the Interior
Components
National Park Service
Report Number
2018-FIN-056
Report Description

This report presents the results of our unannounced inspection on August 14, 2018, of passenger ferry safety at Fort Sumter National Monument, Charleston, SC. The objective of our inspection was to determine whether Fort Sumter Tours, Inc., a National Park Service (NPS) concessionaire, operated its ferry service to Fort Sumter in compliance with Federal safety requirements.Fort Sumter Tours met all the safety requirements that we tested on three of its four vessels (the fourth was out of service). Each had a U.S. Coast Guard Certificate of Inspection on board, and none of the ferries carried more passengers than allowed. Furthermore, the ferries carried enough life vests for all passengers, had fire extinguishers available that had been inspected regularly, and carried first aid kits on board. In addition, sufficient crew members possessed current operating licenses and CPR certifications and passed random drug tests.

Report Type
Inspection / Evaluation
Location

Charleston, SC
United States

Questioned Costs
$0
Funds for Better Use
$0

Department of the Interior OIG

United States