Skip to main content
Report File
Date Issued
Submitting OIG
Tennessee Valley Authority OIG
Other Participating OIGs
Tennessee Valley Authority OIG
Agencies Reviewed/Investigated
Tennessee Valley Authority
Report Number
2021-15802
Report Description

The Office of the Inspector General conducted a review of the John Sevier Combined Cycle (JSCC) Plant to identify factors that could impact JSCC’s organizational effectiveness. During the course of our evaluation, we identified behaviors that had a positive impact on JSCC. These included positive relationships between team members and management; however, we also identified minimal behavioral risks associated with communication and accountability. In addition, we identified minimal risks to operations that, if unaddressed, could hinder JSCC’s effectiveness. These were related to resource needs, such as problems obtaining parts and materials needed to perform jobs, as well as a desire for additional training, including instrument mechanic and instrumentation training.

Report Type
Inspection / Evaluation
Agency Wide
Yes
Number of Recommendations
2
Questioned Costs
$0
Funds for Better Use
$0

Tennessee Valley Authority OIG