Due to TVA aging equipment and the risk parts would be unavailable, the OIG scheduled a review of Hydro Generation obsolete equipment. The objective of our review was to determine if Hydro Generation was effectively managing obsolete equipment. During our review, we found Hydro Generation could more effectively manage obsolete equipment. We found there was no documented guidance to specify how obsolete equipment should be managed. In addition, we found obsolete equipment had extended outage durations. We also found some equipment condition assessments (ECA) included an "Availability of Spare Parts" indicator, which measures the availability and willingness of the original equipment manufacturer to support existing, installed equipment with parts and service; however, the indicator was not always included in the equipment condition assessments.
Report File
Date Issued
Submitting OIG
Tennessee Valley Authority OIG
Other Participating OIGs
Tennessee Valley Authority OIG
Agencies Reviewed/Investigated
Tennessee Valley Authority
Report Number
2015-15265
Report Description
Report Type
Audit
Agency Wide
Yes
Questioned Costs
$0
Funds for Better Use
$0