Submitting OIG:
Report Description:
The Office of the Inspector General conducted a review of Bull Run Fossil Plant (BRF) organization to identify factors that could impact BRF’s organizational effectiveness. Additionally, the scope of this evaluation included identifying lessons learned for future coal plant closures. During the course of our evaluation, we identified positive interactions between coworkers and with various levels of plant management. In addition, TVA’s communication of BRF’s retirement plans, the support provided through Power Operations’ long term workforce strategy, and having an on-site Human Resources representative were seen as positive. However, BRF employees expressed concerns related to: the ability to operate BRF until retirement due to longstanding deteriorated conditions, inadequate staffing, and increased safety risk. We also found opportunities exist to improve site-specific plant knowledge and fire brigade staffing.
Date Issued:
Friday, September 2, 2022
Agency Reviewed / Investigated:
Submitting OIG-Specific Report Number:
2022-17354
Location(s):
Agency-Wide
Type of Report:
Inspection / Evaluation
Questioned Costs:
$0
Funds for Better Use:
$0
Number of Recommendations:
5